Tel:86-15688870591 E-mail:cedric@cedriccn.com
Portable Meters
Portable Meters

3.5-inch color screen, single/multiple parameters optional (pH/ORP/conductivity/DO), and can store 3000 sets of data. Type‑C charging, lithium battery life, IP57 protection, automatic temperature compensation, and timing recording. Equipped with special probe and calibration fluid, it is suitable for high-precision testing in laboratories and on-site.

86-15688870591
cedric@cedriccn.com
Description
图片25

Product Features:

·3.5″ TFT Color Display, easy to read.

·The new UI interface, easy operation.

·Intelligent function with Auto. timing data logger, parameter setting, data holder.

·Data storage up to 3000 groups.

·Cond mode: Support probe constant calibration, conductivity standard solution calibration.

·Power supply: rechargeable lithium battery.

·Charging socket: USB/Type-C, in line with the European new regulations..

·Protection class: IP57.

·Packing size: 400*350*200mm

·Weight: 6kg

 

Product Specification:

Model

PH10

ORP10

EC10

DO10

Polarographic Type

DOPRO10

Optical Type

Parameter

pH/mV.℃

-

-

-

-

mV(ORP).℃

-

-

-

Cond/TDS/Sal./Res.℃

-

-

-

-

DO.℃

-

-

-

PH

Measurement range

(-2.000-20.000)pH

-

-

-

-

Resolution

0.1/0.01/0.001

-

-

-

-

Accuracy

±0.002pH±one digit

-

-

-

-

Calibration points

1, 2, -3pts automatic

-

-

-

-

ATC range

(-10.0-135.0)℃/(14.0-275.0)℉

-

-

-

-

ORP

Measurement range

(-1999.9-+1999.9) mV

-

-

-

Resolution

0.1

-

-

-

Accuracy

±0.03%F.S ±one digit

-

-

-

Conductivity

Measurement

range

0-2000.0mS/cm,

auto-ranging:0-19.999μS/cm;

20.0-199.9μS/cm; 200-1999μS/cm;

2.00-19.99mS/cm;

20.00-199.9mS/cm;

200.0-2000mS/cm(K=10)

Match test range:0-200mS/cm

TDS:0-1000.0g/L(TDS factor adjustable)

Resistivity:

5.000Ω·cm-100.0MΩ·cm

Salinity:0-100 ppt

-

-

-

-

Calibration points

one point

-

-

-

-

Resolution

0.001/0.01/0.1/1

-

-

-

-

ATC range

(0.0-50.0)℃/(32.0-122.0)°F

-

-

-

-

Accuracy

±0.5 % F.S ±one digit

-

-

-

-

DO

Measurement range

(0.00-20.00)mg/L

-

-

-

Accuracy

±0.30 mg/L

-

-

-

-

±0.20 mg/L

-

DO saturation

(0.0-200.0)%




Automatic barometric

pressure compensation

(0-200.0)kPa




Automatic temperature

compensation

(0.0-50.0)℃/(32.0-122.0)℉

-

-

-

Manual salinity

compensation

0-45ppt

-

-

-

Temperature

Measurement range

(-10.0-135.0)℃/(14.0-275.0)℉

Accuracy

±0.2℃

Others

Charging socket

Type-C

Power supply

Rechargeable lithium battery

IP Rating

IP57

Test Kit

Meter

Plastic ATC pH probe 201T-H

-

-

-

-

Plastic ORP probe ORP301

-

-

-

-

Stainless-steel temperature
probe TEMP-02H

-

-

-

-

Plastic ATC Cond probe
CON201T,K=1.0

-

-

-

-

Polarographic DO probe
DO01-2M-H,cable length:2m

-

-

-

-

Optical DO probe
ODO01-3M,cable length:3m

-

-

-

-

pH buffer solution:pH4.00/
7.00/10.01,50mL,one for each

-

-

-

-

Standard ORP
solution:222mV,50mL,1btl

-

-

-

-

Standard Cond
solution:84μS/1413μS/12.88mS/cm,50mL,one for each

-

-

-

-

Membrane refill
solution:DOS-01,30mL,1btl

-

-

-

-

Membrane sensor caps
DOSC:3pcs/group,1pkg

-

-

-

-

Rechargeable lithium
battery(pre-installed)

Charging cable:1pc

Hard carrying case
(L/W/H:33.0*27.2*8.2cm):1pc

 

Product Specification:

Model

PC10

PD10

CD10

PO10

PCD10

Parameter

pH/mV.℃

-

mV(ORP).℃

-

Cond/TDS/Sal./Res.℃

-

-

DO.℃

-

-

PH

Measurement range

(-2.000-20.000)pH

-

Resolution

0.1/0.01/0.001

-

Accuracy

±0.002pH±one digit

-

Calibration points

1, 2, -3pts automatic

-

ATC range

(-10.0-135.0)℃/(14.0-275.0)℉

-

ORP

Measurement range

(-1999.9-+1999.9)mV

-

Resolution

0.1

-

Accuracy

±0.03%F.S ±one digit

-

Conductivity

Measurement range

0-2000.0mS/cm,

Auto-ranging:0-19.999μS/cm;

20.0-199.9μS/cm;200-1999μS/cm;

2.00-19.99mS/cm;

20.00-199.9mS/cm;

200.0-2000mS/cm(K=10)

Match test range:0-200mS/cm

TDS:0-1000.0g/L

(TDS factor adjustable)

Resistivity:5.000Ω·cm-100.0MΩ·cm

Salinity:0-100ppt

-

-

Calibration points

one point

-

-

Resolution

0.001/0.01/0.1/1

-

-

ATC range

(0.0-50.0)℃/(32.0-122.0)℉

-

-

Accuracy

±0.5 % F.S ±one digit

-

-

DO

Measurement range

(0.00-20.00)mg/L

-

-

Accuracy

±0.30 mg/L

-

-

DO saturation

(0.0-200.0)%

-

-

Automatic barometric

pressure compensation

(0-200.0)kPa

-

-

Automatic temperature

compensation

(0.0-50.0)℃/(32.0-122.0)℉

-

-

Manual salinity

compensation

0-45ppt

-

-

Temperature

Measurement range

(-10.0-135.0)℃/(14.0-275.0)℉

Accuracy

±0.2℃

Others

Charging socket

Type-C

Power supply

Rechargeable lithium battery

IP Rating

IP57

Test Kit

Meter

Plastic ATC pH probe 201T-H

-

Plastic ORP probe ORP301

-

-

-

-

Stainless-steel temperature probe
TEMP-02H

-

-

-

-

Plastic ATC Cond probe
CON201T,K=1.0

-

-

Polarographic DO probe
DO01-2M-H,cable length:2m

-

-

pH buffer solution:pH4.00/
7.00/10.01,50mL,one for each

-

Standard ORP solution:222mV,50mL,

1btl

-

-

-

-

Standard Cond solution:84μS/1413μS/

12.88mS/cm,50mL,one for each

-

-

Membrane refill solution:DOS-01,

30mL,1btl

-

-

Membrane sensor caps DOSC:3pcs/

group,1pkg

-

-

Rechargeable lithium battery

(preinstalled)

Charging cable

Hard carrying case

(L/W/H: 36.0*32.0*9.0cm)